-Hazardous
area designation of use: Zone 2 or Class 1, Div 2, Gr A/B/C/D
-Special IP 65 pressurized
cabinet and z-purge controller, complying to II 3G Ex pz II T3 Gc
-On site replaceable detector
head with sensors (O2 & COe)
-Integrated control unit with
backlit display, operating key pad, dual galvanic isolated 4 … 20 mA output and
digital output RS 485 (Modbus RTU)
-Stainless steel SS316Ti flange
4″ ANSI-150Ibs with flow guidance probe tubes, from 11.81“ up to 78.81“ length
-Unique hot solid electrolyte sensor for
combustible COe-measurement without need for sample dilution with air as
required for catalytic bead sensors (Pellistors) (Option)
-Unique blow-back system for dusty flue gases
(Option)
-Integrated auto-calibration for accurate
measurements (Option)
-Dust tight and water proof enclosure, with
optional ATEX heater for very low ambient air temperatures or optional ATEX
Vortec cooler for high ambient temperatures